Customization: | Available |
---|---|
Pattern: | Single Point |
Transform Type: | Resistance Strain |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Specifications | Technique |
Capacity(kg) | 3,5,8,10,15,20,30,35,40,50 |
Accuracy class | C4/C5 |
Rated output | 2.0±0.2 mV/V |
Zero balance | ±2.0%F.S. |
Maximum number of verification intervals | 4000 / 5000 |
Minimum load cell verification interval | 15000 / 20000 |
Combined error | ±0.015%F.S. / ±0.01%F.S. |
Creep(30min) | ≤±0.0184 /±0.0147%F.S. |
Temp.effect on output | ≤±0.087 /0.007%F.S./10ºC |
Temp.effect on zero | ≤±0.009 /0.007%F.S./10ºC |
Input impedance | 460±6Ω |
Output impedance | 350±3Ω |
Insulation | ≥5000MΩ/100VDC |
Recommended excitation | 5~15V |
Maximum excitation | 18V |
Compensated temp range | -10~40ºC |
Operation temp range | -35~65ºC |
Safe overload | 120%F.S. |
Ultimate overload | 150%F.S. |
Cable size | Φ4×4000mm |
Material | Aluminium |
IP Class | IP65 |
Max.platform size | 300mm×300mm |